Civil & special structures · Fos-sur-Mer, France
Seismic study of an oil depot
Seismic vulnerability assessment of steel structures at a classified industrial site.
French rules on classified installations require the seismic vulnerability of equipment that could cause lethal effects in permanently occupied areas to be assessed. Vifatec justified the seismic resistance of the steel frames, modelled in 3D in ANSYS.
Vifatec scope
- Seismic justification of steel frames
- 3D modelling in ANSYS